{"id":42391,"date":"2026-06-17T10:05:15","date_gmt":"2026-06-17T10:05:15","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-360-ica-three-phase-ammeter-including-an-iso-calibration-certificate\/"},"modified":"2026-06-17T10:05:15","modified_gmt":"2026-06-17T10:05:15","slug":"pce-360-ica-three-phase-ammeter-including-an-iso-calibration-certificate","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-360-ica-three-phase-ammeter-including-an-iso-calibration-certificate\/","title":{"rendered":"PCE-360-ICA Three-Phase Ammeter, including an ISO calibration certificate"},"content":{"rendered":"<h2 class=\"main-title main-heading\"><span>PCE-360-ICA Three-Phase Ammeter, including an ISO calibration certificate<\/span><\/h2>\n<div id=\"tab-customdata1\" class=\"tab-pane clear fade in active\">\n<div class=\"usertext\">\n<div>\n<div>\n<div><strong><span>PCE-360-ICA 3-phase ammeter, including an ISO calibration certificate for the power and energy meter (real-time) \/<\/span><\/strong><\/div>\n<div><strong><span>data storage \/ computer interface \/ software<\/span><\/p>\n<p><\/strong><\/div>\n<\/div>\n<div><span>The PCE-360 three-phase ammeter (power analyzer) is used to measure single- or three-phase power. The ammeter\u2019s large display shows up to 10 values at a time. Up to 4 current clamps can be configured simultaneously. In manual mode, the power meter can directly store up to 99 measured values. In data logger mode, up to 20,000 measured values can be stored. This three-phase power meter is therefore ideal for long-term analysis.       <\/span><\/p>\n<p><span>The measured values collected by the device can be transferred to a computer and analyzed as needed. The package includes everything you need for measurement and analysis (including software and a data cable). The power meter is factory-calibrated, but upon request, it can also be laboratory-calibrated and come with an ISO certificate (upon initial order or recalibration, e.g., annually).  <\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata2\" class=\"tab-pane clear fade in \">\n<h1 class=\"headline\"><span>features<\/span><\/h1>\n<div class=\"usertext\">\n<div><span>&#8211; Real-time monitoring, recording, and voltage\/current measurement (true RMS)<\/span><br \/>\n<span>&#8211; measures the power factor and phase angle, as well as active power, apparent power, and reactive power<\/span><br \/>\n<span>&#8211; for measuring the neutral wire with a current clamp<\/span><br \/>\n<span>&#8211; Maximum wire diameter: 40 mm<\/span><br \/>\n<span>&#8211; harmonic (voltage and current harmonics), which can be analyzed using software  <\/span><br \/>\n<span>&#8211; 512 K data logger (20,000 individual measurement channels)<\/span><br \/>\n<span>&#8211; 9 measuring devices<\/span><br \/>\n<span>&#8211; 9 measuring sets. Foldable <\/span><br \/>\n<span>screen<\/span><br \/>\n<span>&#8211; including an ISO calibration certificate<\/span><\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata3\" class=\"tab-pane clear fade in \">\n<h1 class=\"headline\"><span>specification<\/span><\/h1>\n<div class=\"usertext\">\n<table border=\"0\" cellspacing=\"0\" bgcolor=\"#FFFFFF\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"213\"><strong><span>Voltage measurement<\/span><\/strong><\/td>\n<td valign=\"top\" width=\"304\"><span>50 &#8230; 600.0 V true RMS <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+10 digits \/ 0.1 V <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>Current Measurement<\/span><\/strong><\/td>\n<td valign=\"top\"><span>3 &#8230; 999.9 true RMS <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+15 digits \/ 0.1 A<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>Active power P<\/span><\/strong><\/td>\n<td valign=\"top\"><span>150 W&#8230; 999.9 kW <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+20 digits \/ 0.1 kW<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>apparent power S<\/span><\/strong><\/td>\n<td valign=\"top\"><span>150 VA&#8230; 999.9 kVA<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+20 digits \/ 0.1 kVA<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>Reactive power Q<\/span><\/strong><\/td>\n<td valign=\"top\"><span>150 VAR&#8230; 999.9 kVar <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+20 digits \/ 0.1 kV<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>Power Factor PF<\/span><\/strong><\/td>\n<td valign=\"top\"><span>0 &#8230; +1<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>precision<\/span><\/td>\n<td valign=\"top\"><span>\u00b1 0.06<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>0.001<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>phase angle<\/span><\/strong><\/td>\n<td valign=\"top\"><span>-90\u00b0 &#8230;. +90\u00b0<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b1 3\u00b0<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>0.1<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>Frequency measurement (U &gt; 50 V)<\/span><\/strong><\/td>\n<td valign=\"top\"><span>40 &#8230; 100 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11% of the measured value \u00b12 digits<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>0.1 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>Detection of a rotating field (UL &gt; 50 V)<\/span><\/strong><\/td>\n<td valign=\"top\"><span>Yes<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>actual work<\/span><\/strong><\/td>\n<td valign=\"top\"><span>0 &#8230; 9999 MWh <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+20 digits<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>fake work<\/span><\/strong><\/td>\n<td valign=\"top\"><span>0 &#8230; 9999 MVAh<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+20 digits<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><strong><span>offline operation<\/span><\/strong><\/td>\n<td valign=\"top\"><span>0 &#8230; 9999 MVarh <\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Accuracy<\/span><\/td>\n<td valign=\"top\"><span>\u00b11.5% of the measured value<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><span>+20 digits<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Max. current terminal opening<\/span><\/td>\n<td valign=\"top\"><span>40 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Data Storage<\/span><\/td>\n<td valign=\"top\"><span>50 data entries for manual storage<\/span><br \/>\n<span>4 GB SD card for data logging <\/span><br \/>\n<span>(99 storage slots with 350,000 data entries)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>interface<\/span><\/td>\n<td valign=\"top\"><span>Serial via USB cable<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>display<\/span><\/td>\n<td valign=\"top\"><span>Backlit LCD screen<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Offer<\/span><\/td>\n<td valign=\"top\"><span>8 x 1.5 V AA (Mignon)<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Dimensions<\/span><\/td>\n<td valign=\"top\"><span>235 x 117 x 54 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Weight<\/span><\/td>\n<td valign=\"top\"><span>730 g<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Environmental Conditions<\/span><\/td>\n<td valign=\"top\"><span>max 85% relative humidity \/ 0 &#8230; +40 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Protection Class \/ Standardization<\/span><\/td>\n<td valign=\"top\"><span>IP 30 \/ IEC 61 010, 600 V \/ CAT III<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"tab-customdata4\" class=\"tab-pane clear fade in \">\n<h1 class=\"headline\"><span>scope of delivery<\/span><\/h1>\n<div class=\"usertext\">\n<div><span>1 x 3-phase ammeter PCE-360-ICA<\/span><br \/>\n<span>4 x power clamps  <\/span><br \/>\n<span>4 x insulated alligator clips, each on a 3-meter cable  <\/span><br \/>\n<span>4 x safety measurement cables<\/span><br \/>\n<span>8 batteries  <\/span><br \/>\n<span>1 x power adapter  <\/span><br \/>\n<span>1 x carrying bag  <\/span><br \/>\n<span>1 x USB computer cable<\/span><br \/>\n<span>1 x software (English, with German descriptions and illustrations)  <\/span><br \/>\n<span>1 x user manual  <\/span><br \/>\n<span>1 ISO calibration certificate<\/span><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3 class=\"main-title main-heading\"><span>PCE-360-ICA Three-Phase Ammeter, including an ISO calibration certificate<\/span><\/h3>\n<div><strong>PCE-360-ICA 3-phase ammeter, including ISO calibration certificate for power and energy meters (real-time) \/<\/strong><\/div>\n<div><strong>data storage \/ computer interface \/ software<\/strong><\/div>\n","protected":false},"featured_media":42394,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"PCE-360-ICA Three-Phase Ammeter ISO Certificate","_seopress_titles_desc":"PCE-360-ICA Three-Phase Ammeter, ISO, including ISO calibration certificate for power and energy meters, data logging, computer interface, software","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1003,975],"product_tag":[],"class_list":["post-42391","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-digital-multimeters","product_cat-measuring-instruments","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/42391","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/42394"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=42391"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=42391"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=42391"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=42391"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}