{"id":42377,"date":"2026-06-17T10:05:38","date_gmt":"2026-06-17T10:05:38","guid":{"rendered":"https:\/\/proair.ee\/toode\/uv-meter-uv-tester-pce-em-890\/"},"modified":"2026-06-17T10:05:38","modified_gmt":"2026-06-17T10:05:38","slug":"uv-meter-uv-tester-pce-em-890","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/uv-meter-uv-tester-pce-em-890\/","title":{"rendered":"UV Meter \/ UV Tester PCE-EM 890"},"content":{"rendered":"<h2 class=\"main-title main-heading\">UV Meter \/ UV Tester PCE-EM 890<\/h2>\n<div id=\"tab-customdata1\" class=\"tab-pane clear fade in active\">\n<div class=\"usertext\">\n<div><strong>UV Meter \/ UV Tester for recording various environmental data \/ Various measurement functions \/ MAX \/ MIN measurements \/ High accuracy  <\/strong><\/div>\n<div><\/div>\n<div>\n<p>A UV meter \/ UV tester is a device for measuring environmental conditions. The UV meter \/ UV tester provides you with accurate measurements very quickly. Thanks to its compact size and light weight, this UV meter \/ UV tester is an easy-to-use weather monitoring tool. You can switch between measurement functions with just the press of a button. Therefore, this UV meter\/UV tester is ideal for technicians, sailors, farmers, and many others who depend on the weather or whose activities are significantly affected by it.    <\/p>\n<p>With just one display, you can read<strong> wind speed, temperature, wind chill (feels-like temperature), dew point, relative humidity, heat index, air pressure, and altitude above sea level<\/strong>. The UV meter\/UV tester offers functions for measuring individual readings, minimum values, and maximum values. <\/p>\n<p>ACCESSORY &#8211;<\/p>\n<h3 class=\"main-title main-heading\">PT-1000 Temperature Sensor PCE-EM 890-TP &#8211; Price: 48 euros, shipping included<\/h3>\n<p><a href=\"http:\/\/proair.ee\/wp-content\/uploads\/2025\/02\/pce-instruments-pt-1000-temperature-sensor-pce-em-890-tp-5973089_1731331.webp\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-37398\" src=\"http:\/\/proair.ee\/wp-content\/uploads\/2025\/02\/pce-instruments-pt-1000-temperature-sensor-pce-em-890-tp-5973089_1731331-300x300.webp\" alt=\"accessory\" width=\"300\" height=\"300\"><\/a><\/p>\n<p>Explanation of various environmental conditions:<\/p>\n<p><strong>Wind chill<\/strong><br \/>\nWind chill describes the difference between the measured air temperature and the perceived temperature as a function of wind speed. Some of our UV meters\/UV testers can record wind chill and other parameters. <\/p>\n<p><strong>Air Pressure<\/strong><br \/>\nThe air pressure at any point in Earth\u2019s atmosphere is the hydrostatic pressure of the air at that point. This pressure corresponds to the weight of the column of air above the Earth\u2019s surface or of an object located within it. The average atmospheric pressure at sea level is 101,325 Pa = 1,013.25 hPa = 101.325 kPa and is therefore part of standard conditions.<\/p>\n<p><strong>Dew point \/ Dew point temperature<\/strong><br \/>\n Air can absorb more water vapor as the temperature increases. When the temperature of the building material or air, which has reached 100% relative humidity, drops, the excess water vapor condenses as condensation. The boundary area is called the dew point. Buildings should be designed so that the dew point temperature on the inside of the air tightness layer does not fall below. This prevents the formation of condensation and the resulting structural damage or mold. Air currents through the air tightness layer are particularly harmful. In this case, a drop in the dew point is always expected. The wet bulb temperature, which plays an important role in the air conditioning industry, for example, is a very important parameter in many other areas.       <\/p>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"tab-customdata2\" class=\"tab-pane clear fade in \">\n<p><strong>Highlights<\/strong><br \/>\n&#8211; compact and durable design<br \/>\n&#8211; high accuracy<br \/>\n&#8211; highly accurate, smooth-running impeller<br \/>\n&#8211; easy-to-read digital display<br \/>\n&#8211; backlight<br \/>\n&#8211; replaceable impeller<br \/>\n&#8211; Max-Min measurement<br \/>\n&#8211; 11 measurement functions in one device<\/p>\n<p><strong>Specifications<\/strong><\/p>\n<\/div>\n<div id=\"tab-customdata3\" class=\"tab-pane clear fade in \">\n<div class=\"usertext\">\n<table>\n<tbody>\n<tr>\n<td width=\"156\"><strong>Measurement Function<\/strong><\/td>\n<td width=\"122\"><strong>Measurement Range<\/strong><\/td>\n<td width=\"90\"><strong>Resolution<\/strong><\/td>\n<td width=\"160\"><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Wind speed<\/strong><\/td>\n<td>80 &#8230; 3,937 feet\/min<\/td>\n<td>1 foot\/min<\/td>\n<td>\u00b1 3% of the measured value<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0.4 &#8230; 20 m\/s<\/td>\n<td>0.1 m\/s<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>1.4 &#8230; 72 km\/h<\/td>\n<td>0.1 km\/h<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0.9 &#8230; 44.7 mph<\/td>\n<td>0.1 miles per hour<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0.8 &#8230; 38.8 knots<\/td>\n<td>0.1 knots<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Air Temperature<\/strong><\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0 &#8230; 50 \u00b0C \/ 32 &#8230; 122 \u00b0F<\/td>\n<td>0.1 \u00b0C \/ 0.18 \u00b0F<\/td>\n<td>\u00b1 1.2 \u00b0C \/ 2.16 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Humidity<\/strong><\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>10&#8230;95% relative humidity<\/td>\n<td>0.1% relative humidity<\/td>\n<td>&lt;70% relative humidity: \u00b1 4% relative humidity<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td>&gt;70% rH: \u00b1 4 of the measured value +1.2% rH<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Barometric-<\/strong><\/td>\n<td><strong>Measurement Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>air pressure<\/strong><\/td>\n<td>10 &#8230; 999.9 hPa<\/td>\n<td>0.1 hPa<\/td>\n<td>\u00b1 1.5 hPa<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>1000 &#8230; 1100 hPa<\/td>\n<td>1 hPa<\/td>\n<td>\u00b1 2 hPa<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>UV-A<\/strong> 290 &#8230; 390 nm<\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0 &#8230;. 1999 \u00b5W\/m\u00b2<\/td>\n<td>0.1 \u00b5W\/m\u00b2<\/td>\n<td>\u00b1(4% of the measured value + 2 digits)<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>2 &#8230; 20 mW\/m\u00b2<\/td>\n<td>0.01 mW\/m\u00b2<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Outdoor Temperature<\/strong><\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>(Pt1000 input)<\/strong><\/td>\n<td>-10 &#8230; 70 \u00b0C \/ 14 &#8230; 158 \u00b0F<\/td>\n<td>0.1 \u00b0C \/ 0.18<\/td>\n<td>\u00b1 1.2 \u00b0C \/ 2.16 \u00b0F<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Volume Flow<\/strong><\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0.024 &#8230; 3,600 cm<\/td>\n<td>0.001 cm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>0.01 cm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>0.1 cm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>1 cm<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><strong>Measurement Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Dew point<\/strong><\/td>\n<td>-25.3 &#8230; 49 \u00b0C \/ 13.54 &#8230; 120.2 \u00b0F<\/td>\n<td>0.1 \u00b0C \/ 0.18 \u00b0F<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Wet bulb temperature<\/strong><\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>-5.4 &#8230; 49 \u00b0C \/ 22.28 &#8230; 120.2 \u00b0F<\/td>\n<td>0.1 \u00b0C \/ 0.18 \u00b0F<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Heat Stress Index<\/strong><\/td>\n<td><strong>Measurement Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>0 &#8230; 100 \u00b0C \/ 32 &#8230; 212 \u00b0F<\/td>\n<td>0.1 \u00b0C \/ 0.18 \u00b0F<\/td>\n<td>\u00b1 2\u00b0C \/ 3.6\u00b0F<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Wind Chill<\/strong><\/td>\n<td><strong>Measurement Range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>-9.4 &#8230; 44.2 \u00b0C \/ 15.8 &#8230; 111.56 \u00b0F<\/td>\n<td>0.1 \u00b0C \/ 0.18 \u00b0F<\/td>\n<td>\u00b1 2\u00b0C \/ 3.6\u00b0F<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Elevation above sea level<\/strong><\/td>\n<td><strong>Measurement range<\/strong><\/td>\n<td><strong>Resolution<\/strong><\/td>\n<td><strong>Accuracy<\/strong><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>-2,000 &#8230; 9,000 m \/ -6,561 &#8230; 29,527 feet<\/td>\n<td>1 m \/ 3 feet 3&#8243;<\/td>\n<td>\u00b1 15 m<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\"><strong>General Technical Specifications for the Anemometer<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Screen<\/td>\n<td colspan=\"2\">LC screen<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">8 mm character height<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Measurement Functions<\/td>\n<td colspan=\"2\">Wind Speed\/Temperature<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Display Parameters<\/td>\n<td colspan=\"2\">Humidity \/ Temperature<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">UV<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Air Pressure<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Volume flow<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Dew Point<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Temperature of a wet pear<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Wind chill<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Heat Stress Index<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Elevation above sea level<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\">Outdoor temperature above 1000 Pt<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\"><\/td>\n<td colspan=\"2\"><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Power Source<\/td>\n<td colspan=\"2\">CR2032 3V batteries<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Current consumption<\/td>\n<td colspan=\"2\">approx. 5 mA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Operating Conditions<\/td>\n<td colspan=\"2\">0 &#8230; 50 \u00b0C \/ 32 &#8230; 122 \u00b0F \/ max. 80% relative humidity<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Dimensions<\/td>\n<td colspan=\"2\">120 x 45 x 20 mm \/ 4.7 x 1.7 x 0.7 inches<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Weight<\/td>\n<td colspan=\"2\">approx. 160 g \/ &lt; 1 pound<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h2 class=\"main-title main-heading\">UV Meter \/ UV Tester PCE-EM 890 (<strong>wind speed, temperature, wind chill (felt temperature), dew point, relative humidity, heat index, air pressure, and altitude above sea level)<\/strong><\/h2>\n<p>A UV meter \/ UV tester is a device for measuring environmental conditions. The UV meter \/ UV tester provides you with accurate measurements very quickly. Thanks to its compact size and light weight, this UV meter \/ UV tester is an easy-to-use weather monitoring tool. You can switch between measurement functions with just the press of a button. Therefore, this UV meter\/UV tester is ideal for technicians, sailors, farmers, and many others who depend on the weather or whose activities are significantly affected by it.    <\/p>\n<p>With just one display<strong>,<\/strong> you can read<strong> wind speed, temperature, wind chill (feels-like temperature), dew point, relative humidity, heat index, air pressure, and altitude above sea level<\/strong><\/p>\n","protected":false},"featured_media":42379,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"UV Meter \/ UV Tester PCE-EM 890","_seopress_titles_desc":"Measuring instruments\u2014wind speed, temperature, wind chill (perceived temperature), dew point, relative humidity, heat index, air pressure, and elevation above sea level","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"none","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[1000,975,1002,976,1001],"product_tag":[],"class_list":["post-42377","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-airflow","product_cat-measuring-instruments","product_cat-radiation-detector","product_cat-temperature-and-humidity","product_cat-wind-speed-monitoring-station","first","instock","taxable","shipping-taxable","purchasable","product-type-variable"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/42377","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/42379"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=42377"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=42377"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=42377"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=42377"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}