{"id":42335,"date":"2026-06-17T10:06:22","date_gmt":"2026-06-17T10:06:22","guid":{"rendered":"https:\/\/proair.ee\/toode\/pce-mnd-10-ica-noise-meter-with-iso-calibration-certificate\/"},"modified":"2026-06-17T10:06:22","modified_gmt":"2026-06-17T10:06:22","slug":"pce-mnd-10-ica-noise-meter-with-iso-calibration-certificate","status":"publish","type":"product","link":"https:\/\/proair.ee\/en\/toode\/pce-mnd-10-ica-noise-meter-with-iso-calibration-certificate\/","title":{"rendered":"PCE-MND 10-ICA Noise Meter with ISO Calibration Certificate"},"content":{"rendered":"<h2>PCE-MND 10-ICA Noise Meter with ISO Calibration Certificate<\/h2>\n<h3>Noise meter in accordance with standard IEC 61252:2002 \/ Measurement range 70 &#8230; 140 dB \/ Alligator clips \/<br \/>\nfor use in ensuring workplace safety \/ Battery life &gt;15 hours \/ USB interface \/<br \/>\nKey lock \/ Frequency weighting A, C, and Z<\/h3>\n<p><iframe loading=\"lazy\" title=\"Exact measurement of noise exposure at the work - Sound Level Meter PCE-MND 10 | #pceinstruments\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/6mQ2-hpRy4I?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<p>This noise meter has been specifically designed to measure noise exposure in the workplace and complies with the IEC 61252:2002 standard. With a measurement range of 70\u2013140 dB and frequency weightings A, C, and Z, the sound level meter is ideal for this purpose. The time-averaging mode of the sound level meter can be set to fast, slow, or impulse. With its built-in 470 mAh battery, the sound level meter has an operating time of 15 hours ( &gt;).   <\/p>\n<p>Up to three virtual sound level meters can be configured on a single sound level meter. The advantage of this is that up to three measurement standards can be measured simultaneously. The sound level meter\u2019s display has up to 14 measurement windows, each of which can be adjusted individually.  <\/p>\n<p>Data is transferred from the noise meter to the computer directly via the charging station. The noise meter\u2019s software allows you to view and analyze the stored measurement data. In addition, all settings for the noise meter can be configured through the software. Another unique feature of the noise meter is that the charging stations can be connected to each other. The advantage of this is that multiple noise meters can be charged from a single power source. Up to four noise meters can be charged simultaneously from a single power source.     <\/p>\n<p>To ensure optimal stability and positioning, the noise meter is attached to the worker\u2019s work clothes using two alligator clips. The distance between the ear and the noise meter should be between 10 and 15 cm. <\/p>\n<p><strong>&#8211; Frequency weighting A, C, and Z<\/strong><br \/>\n<strong>&#8211; Battery life &gt;: 15 hours<\/strong><br \/>\n<strong>&#8211; For configuring software parameters<\/strong><br \/>\n<strong>&#8211; Measurement range: 70 &#8230; 140 dB<\/strong><br \/>\n<strong>&#8211; IEC 61252:2002, ANSI S1.25-1991<\/strong><\/p>\n<div id=\"tab-customdata3\" class=\"tab-pane clear fade in \">\n<div class=\"usertext\">\n<table border=\"0\" cellspacing=\"0\" bgcolor=\"#FFFFFF\">\n<tbody>\n<tr>\n<td valign=\"top\"><strong><span>Measurement range<\/span><\/strong><\/td>\n<td valign=\"top\"><strong><span>70\u2026140 dB (A, C)<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><strong><span>90\u2026140 dB (Z)<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Measurement range (peak value)<\/span><\/td>\n<td valign=\"top\"><span>103 \u2026 143 dB PEAK<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>resolution<\/span><\/td>\n<td valign=\"top\"><strong><span>0.1 dB<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>precision<\/span><\/td>\n<td valign=\"top\"><span>2nd grade<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Frequency range<\/span><\/td>\n<td valign=\"top\"><span>31.5 Hz \u2026 8 kHz<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Frequency Estimates<\/span><\/td>\n<td valign=\"top\"><span>A, C, and Z<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Assessing Time<\/span><\/td>\n<td valign=\"top\"><span>fast, slow, impulse<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Adjustable gain<\/span><\/td>\n<td valign=\"top\"><span>3, 4, 5, 6 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Threshold adjustment range<\/span><\/td>\n<td valign=\"top\"><span>70\u202690 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Threshold resolution<\/span><\/td>\n<td valign=\"top\"><span>1 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Criterion Level Adjustment Range<\/span><\/td>\n<td valign=\"top\"><span>70\u202690 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Criteria-Level Resolution<\/span><\/td>\n<td valign=\"top\"><span>1 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Displayed when ambient noise is too loud <\/span><\/td>\n<td valign=\"top\"><span>&gt;115 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>memory<\/span><\/td>\n<td valign=\"top\"><span>30 measurement runs in total<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>  6,101 measurement points<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>timer<\/span><\/td>\n<td valign=\"top\"><span>16 timers for automatic operation<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>Data Storage and 99 Timers<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Warm-up time<\/span><\/td>\n<td valign=\"top\"><span>10 seconds after turning it on<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>microphone<\/span><\/td>\n<td valign=\"top\"><span>1\/2-inch electret condenser<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Display<\/span><\/td>\n<td valign=\"top\"><span>128&#215;64-pixel LCD screen<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>For use in accordance with the standard<\/span><\/td>\n<td valign=\"top\"><span>IEC 61252:2002, ANSI S1.25-1991<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Number of virtual dosimeters<\/span><\/td>\n<td valign=\"top\"><span>3<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Dosimeter Standards<\/span><\/td>\n<td valign=\"top\"><span>OSHA-80, OSHA-90, MSHA-80, MSHA-90, DOD,<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>ACGIH, ISO-85, ISO-90, NR-15, NHO-01<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>In addition, up to 9 individuals<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>The standards have been saved<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Measurement Parameters for All<\/span><\/td>\n<td valign=\"top\"><span>DOOS (dose), PDOSE (Pdos), TWA (Twa),<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>virtual dosimeter<\/span><\/td>\n<td valign=\"top\"><span>PTWA (PTwa), LAVG (Lavg), LEPd (Lepd),<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>PLEPd (PLepd), overshoot time<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>(Let&gt;105 or Let&gt;115),  <\/span><strong><span>LEQ<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>(Laeq, Lceq, Lzeq), SEL (LaE, LCE, or LZE),<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>SEpa2h (Ea, Ec, Ez), PEAK (Pka, Pkc, or Pkz),<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>LEX8H (Lex8h), PLEX8H (PLEX8h),<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>EXPHrs (Exph), EXPsec (Exps), NEN<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Additional Measurement Parameters<\/span><\/td>\n<td valign=\"top\"><span>MAX\/MIN, L05, L10, L50,<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>The first virtual dosimeter<\/span><\/td>\n<td valign=\"top\"><span>L90 and L95 at 20 ms intervals<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>and a difference of 0.1 dB,<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>LAEQ05, LAEQ10, LAEQ50, LAEQ90,<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>LAEQ95 with a 1-second interval<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>and a difference of 0.1 dB<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>interface<\/span><\/td>\n<td valign=\"top\"><span>USB port on the charging station<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Power Source (Battery)<\/span><\/td>\n<td valign=\"top\"><span>3.7 V, 470 mAh, lithium-polymer battery<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Power Supply (Power Supply)<\/span><\/td>\n<td valign=\"top\"><span>Primary: 100 &#8230; 240 V AC, 50 &#8230; 60 Hz, 0.7 A<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>Secondary: 9 V DC, 2 A<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Operating time<\/span><\/td>\n<td valign=\"top\"><span>&gt;15 hours at 23 \u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Operating Conditions<\/span><\/td>\n<td valign=\"top\"><span>0 &#8230; 50 \u00b0C (32 &#8230; 122 \u00b0F), 10 &#8230; 95% relative humidity,<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>non-condensing<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Storage Conditions<\/span><\/td>\n<td valign=\"top\"><span>-10 \u2026 +60 \u00b0C (14 \u2026 140 \u00b0F), 10 \u2026 75% relative humidity,<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><span>non-condensing<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Dimensions<\/span><\/td>\n<td valign=\"top\"><span>84 x 49 x 55 mm \/ 3.3 x 1.9 x 2.2 inches<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><span>Weight<\/span><\/td>\n<td valign=\"top\"><span>77 g<\/span><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><\/td>\n<td valign=\"top\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div id=\"tab-customdata4\" class=\"tab-pane clear fade in \">\n<div class=\"usertext\">Scope of delivery<br \/>\n, 1 x PCE-MND 10 noise meter-ICA<br \/>\n1 x USB cable<br \/>\n1 x charging station with power supply<br \/>\n1 x power adapter<br \/>\n1 x mounting bracket<br \/>\n1 x software CD<br \/>\n1 x carrying case<br \/>\n1 x user manual<br \/>\n1 x ISO calibration certificate<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3>PCE-MND 10-ICA Noise Meter with ISO Calibration Certificate<\/h3>\n<div><span>&#8211; Frequency weighting A, C, and Z<\/span><\/div>\n<div><span>&#8211; Battery life &gt;: 15 hours<\/span><\/div>\n<div><span>&#8211; For configuring software parameters<\/span><\/div>\n<div><span>&#8211; Measurement range: 70 &#8230; 140 dB<\/span><\/div>\n<div><span>&#8211; IEC 61252:2002, ANSI S1.25-1991<\/span><\/div>\n","protected":false},"featured_media":42336,"template":"","meta":{"_acf_changed":false,"_seopress_titles_title":"PCE-MND 10-ICA Noise Meter with ISO Calibration Certificate","_seopress_titles_desc":"PCE-MND 10-ICA noise meter with an ISO calibration certificate. Noise meter compliant with standard IEC 61252:2002 \/ Measurement range 70 ... 140 dB","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"both","_seopress_redirections_param":"","_seopress_redirections_type":301,"_seopress_analysis_target_kw":""},"product_brand":[739],"product_cat":[975,981],"product_tag":[],"class_list":["post-42335","product","type-product","status-publish","has-post-thumbnail","product_brand-pce-deutschland-gmbh","product_cat-measuring-instruments","product_cat-noise-meter","first","instock","taxable","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product\/42335","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media\/42336"}],"wp:attachment":[{"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/media?parent=42335"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_brand?post=42335"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_cat?post=42335"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/proair.ee\/en\/wp-json\/wp\/v2\/product_tag?post=42335"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}